

⚙️ Elevate your diagnostics—where precision meets portability!
The Hantek 6022BL is a compact, USB-powered digital storage oscilloscope featuring 2 analog and 16 logic channels, 48MSa/s sampling rate, and 20MHz bandwidth. Its durable anodized aluminum case and versatile measurement functions make it ideal for engineers and technicians seeking high-performance, portable signal analysis without external power requirements.









| ASIN | B01M74UKKC |
| ASIN | B01M74UKKC |
| Batteries Included? | No |
| Batteries Required? | No |
| Customer Reviews | 4.0 4.0 out of 5 stars (159) |
| Customer reviews | 4.0 4.0 out of 5 stars (159) |
| Date First Available | 4 October 2017 |
| Date First Available | 4 October 2017 |
| Is Discontinued By Manufacturer | No |
| Item Package Quantity | 1 |
| Item Weight | 299 g |
| Manufacturer | Hantek |
| Manufacturer | Hantek |
| Manufacturer reference | 6022BL |
| Manufacturer reference | 6022BL |
| Part number | 6022BL |
| Product Dimensions | 20 x 3.5 x 10 cm; 299.37 g |
| Product Dimensions | 20 x 3.5 x 10 cm; 299.37 g |
P**�
Excelente producto. Los recomiendo.
A**R
I bought this for the odd occasions when I absolutely have to float the ground connection or when only a battery powered ultra portable 'scope will do. At timebase settings of 2us/div and under it takes about 1000 samples at a time at the full 48Ms/s rate. By default, the supplied software performs sinusoidal interpolation which means with care you can use the scope on waveforms quite close to the Nyquist limit. At 5us/div and up it samples at a lower rate of 16Ms/s or less. Whilst this makes sense given the display resolution, it does mean that aliasing becomes an issue and glitches will most likely be missed. The free third party software "BasicScope" uses the sample buffer to provide a very effective delayed trigger function. The input attenuator provides real sensitivities of 100, 200, 500 and 1000mV/div. All other ranges are implemented in software. Inputs clip at +/-5V so 2 and 5V/div ranges are of limited use. This isn't too much of an issue as the good quality 'scope probes supplied are *10 or *1 switched. DC coupling only. The logic analyser software supplied is rather limited. It doesn't even have a waveform trigger function. Fortunately, there is a sneaky switch which allows the logic analyser to be used with third party software. This does provide a number of trigger functions and understands common protocols. 20 good quality probe clips are included for use on DIL ICs in case anyone still uses these! I could not get the drivers on the software CD to install and ended up using the ones downloaded from the Hantek web site. Under XP these installed as per the instructions but on 7 I had to do a manual installation through the Device Manager. Since first posting this review I have written oscilloscope software specifically for this model. This runs under Linux and is available on GitHub as the "Hantek-6022BL". It overcomes a lot of the shortcomings of the Windows software providing much improved performance at 48Ms/s with five fold upsampling, more robust trigger, delayed trigger, hold off, add, invert and variable vertical sensitivity. A 16Ms/s sampling rate is maintained down to 5ms/div so that a special "glitch" mode can display short pulses which would normally be missed.
A**S
Das Hantek 6022BL funktioniert sehr gut, wenn nicht die mitgelieferte Software von Hantek verwendet wird. Ich habe nach Alternativen gesucht und unter Windows 10 und Linux ausprobiert. Ich habe schnell eine Software (Open Source) gefunden, die es ermöglicht mehrere Minuten ohne Unterbrechung bei hoher Frequenz aufzuzeichnen. (Gibt es für Linux und Windows - hab nur die Linux Variante getestet). Die Aufzeichnung wird dabei auf dem Bildschirm life aktualisiert, was recht hilfreich ist, wenn man nach sporadischen Fehlerquellen suchen muss und kann danach bequem ausgewertet / gespeichert werden. Vor dem Anstecken des Gerätes am USB Anschluss muss gewählt werden, ob man es als Oszilloskop verwenden möchte oder als Logic Analyzer. (Button nebem USB Buchse). Zum Umschalten des Modus muss das Gerät erst ausgesteckt werden - andernfalls ist es bei mir zu Fehlern mit dem Treiber gekommen und das Gerät ist erst wieder nach Aus- und Einstecken wieder verwendbar. Leider ist davon nicht viel in der Anleitung zu finden. Diese ist sehr schlecht beschrieben, was die Benutzung des Gerätes betrifft. Ingesamt bin ich für diese Preisklasse mit dem Messergebnis sehr zufrieden und durch die alternative Software ist das Gerät sehr gut für Hobbyzwecke verwendbar: Kurz getestet mit folgenden Aufbauten: LogicAnalyzer: SingleWire und I²C (max. 5V!) Oszilloskop: Spannungsregler Verhalten 5V und 3.3V (max. 35V) Das Zubehör macht einen guten Eindruck und reicht für die meisten Messungen gut aus.
J**G
Considero que la relación calidad/precio es muy buena. llegó antes del plazo de entrega, perfectamente protegido, Lo adquirí para poder compara el funcionamiento de los inyectores de mi coche, como se puede ver en el video, funcionó perfectamente, Recomendable si lo que buscas no es un equipo de altísimas prestaciones.
D**O
All'inizio ho avuto problemi, dopo aver installato e lanciato il file d'avvio, non si apriva nessun programma senza scrivere nessuna anomalia. Dopo diverse verifiche ho scoperto che, seppure durante l'installazione ti chiede dove vuoi installare il software, il programma non funziona se si installa in un hard disk diverso da "C". Risolto questo problema il programma si apre regolarmente. Nei prossimi giorni proverò l'oscilloscopio.
Trustpilot
1 month ago
1 week ago