⚙️ Elevate your motor control game — power, precision, and peace of mind in one sleek drive!
The HY HUANYANG GT Series Variable Frequency Drive delivers robust 11KW (15HP) motor speed control by converting single-phase 220VAC input to 3-phase output. Featuring advanced vector control, RS-485 communication, and remote speed adjustment, it ensures efficient, low-noise operation with CE certification and a 1-year replacement warranty, making it a reliable choice for both professional and hobbyist applications.






| ASIN | B07G97DQQ5 |
| Best Sellers Rank | #65,751 in Industrial & Scientific ( See Top 100 in Industrial & Scientific ) #37 in Motor Speed Controllers |
| Brand | HY HUANYANG |
| Color | 220V 1or3 phase input-11kw(15hp) |
| Customer Reviews | 4.1 out of 5 stars 284 Reviews |
| Electrical Output Waveform | Pure Sine Wave |
| Energy Specifications Met | CE |
| Frequency | 60 Hz |
| Input Voltage | 220 Volts |
| Item Height | 11.81 inches |
| Item Weight | 16 Pounds |
| Manufacturer | Huanyang Electrical |
| Model Name | GT-011G-2 |
| Model Number | 220V 1/3 phase input to 3 phase-11kw |
| Output Power | 11000 Watts |
| Output Voltage | 220 Volts |
| Peak Output Power Watts | 16500 |
| Power Source | ac |
| Standby Power Shutoff | 90 |
| UPC | 724509859647 |
| Voltage | 220 Volts |
| Wattage | 11 KW |
S**D
Great warranty support, great features for the price, time will tell about long term reliability
I received a defective 7.5KW VFD. I contacted Amazon for warranty support, and Amazon directed me to Huanyang. I contacted Huanyang, and after a brief exchange of steps to debug and the results, Huanyang agreed to send me a replacement unit. The replacement arrived within a couple of days of our exchange. The replacement works perfectly. Time will tell if it holds up, but I am very pleased with the support I received. There are mixed reviews of this unit, but most problems seem to be evident right out of the box or upon initial powerup. That was true in my case - unit reset itself randomly right out of the box. This replacement is working as expected, so I am hoping it stays that way. There are more expensive options, and there are also cheaper options, but I really like the features and function of this box so, fingers crossed.
M**R
2 year old, no problems.
Why did you pick this product vs others?: I have been using this VFD on my 7.5hp 16" Delta radial arm saw for about 2 years now. It has been working perfectly. I also have some name brand VFD's to run my 3 phase machines on Single phase. These inexpensive VFD's are a lot easier to setup. They have a fraction of the possible setup parameters of my Hitachi VFD's but I don't have any need for the fancy parameters and they really just get in the way making initial configuration more difficult. If your income depends on the proper functioning of your machinery I can see why you would want to use a name brand VFD with good support and a good warranty. But if you are a hobby guy like me these VFD's are a great value!
P**H
Excellent product if you get educated in advance
I bought this to run a 2HP motor on a Bridgeport copy that is 3 phase. Like others say, the manual has some errors. It shows on the wiring page to hook up the single phase power to R and T. It didn't work that way. Hook it up to R and S. The best advice I can give is that before you order it spend some time on YouTube to see where others have struggled or succeeded . Do a search for "Huanyang GT" There you will find several videos including "VFD GT series operation" I took my laptop to the shop and followed it step by step. It ran perfectly with no issues at all and I have never wired a VFD. Watching videos will get you familiar with the functions. Great bargain for the money if you have some electrical skills! You will need to wire in a disconnect and likely low voltage control wiring. I went through the extra effort to install it in a enclosure. EDIT: After a successful install, I bought another larger unit for my 5hp Lathe. More challenging to install but well worth the effort. The amount of electrical hardware you get to remove is staggering! My personal opinion is to stay away from "Autotune" and just enter your basic motor parameters and HZ. Start slowly. As you learn the programming language things will start to click and make sense. Managed to get everything programmed exactly how I wanted it including the mechanical brake. Great product for the money. Patience.....required for this project but I couldn't be happier with the results!
A**R
Someone is going to get hurt!
I'm currently dealing with the breaking resistor ...scam? I don't know what the deal is but after many emails back and forth I was told the top of their line 7.5kw model is the only one that comes ready to accept a resistor and so I shelled out the extra cash for it, many emails later i was told a 1000W 75ohm resistor was acceptable for this unit.. with everything wired as per their videos I hit start and let the bandsaw get up to speed, as soon as I hit the stop button it VIOLENTLY EXPLODED with my hand on the unit! sparks blew 3 feet out of the side vents in both directions. First I was told the problem was that my motor had to be three phase so I sent a photo confirming it is indeed a three phase motor. next my wiring was wrong so I sent photos of my wiring only to be told it was wrong with advice to connect it exactly as I had it. Finally, after sending a home video showing all my connections and terminations I'm told I connected my resistor wrong.. get this.. "I should connect to the brackets that hold the resistor in place instead of the coil terminals" What!? that sounds like an expensive jumper and not a resistor. the unit was actually running my bandsaw but if breaking is not a viable function why sell it as having it and then run me in circles when it blows up!? I'm told they're sending another unit, if they do I guess I won't try to use a breaking resistor as I can't get useful or accurate information from the source. I've seen videos of these units with a resistor working, was I given bogus information on the resistor value, can anyone confirm? I have a 220 3hp 2.2kw 60hz 9.1A motor in delta configuration running a 24" bandsaw.
L**C
It's working!!!
At this price, I can't believe it work and work fine. I did get this one for a hydraulic system 7.5HP 230V/460V. 3phases to run on 230v split-phase (or single phase if you like better, same thing) Scotchman 90T Ironworker. I did add the remote control to have the drive control in my face and the AC drive way in the back where nothing can hit-it or chip getting inside. It work flawlessly or almost. I usually use the Mitsubishi drive but the remote was a nice thing on this one at 1/4 of the price. I didn't expect-it to work, but I'm please about-it for the price. It's not all good, there's few draw-back and limitation that make-it limited depend on the application. As expected the instruction S#<k and very confusing. The ground is not clearly identify and the connection strip pin identification different in the book... Yes RST and UVW are clear, Ro and R1 are probably for a resistor that doesn't work, be back on this. And the first "ES" or "E" or connector"1" (depend where you look) is the ground, Frame, Earth and should be green... No the dynamic break doesn't work, it's an option. In my case, it's fine but if you drive a cutting tool and you need to stop fast, look for that option or an other drive that include that option and pay few more big one... The software and parameters set-up is good but instructions s#<k and will confused you. I'm not sure if it's me but couldn't have the pot (Speed control) working when I have an external E-Stop install?!?! And the last thing (more like bitching) that nosy little fan, it work all the time and it is load in little fan goes. There's a parameter that set-it to start at a certain temperature but mine turn on when the power is on and turn off when the power is off no matter if I have-it on temperature control... No need to add a light to tell me the machine is under power ;-) Oh I forgot the split phase issue / 3ph intake, again confusing. In the book, it clearly say to use-it on 3 phases and is not listed as being a single phase. There selection say split phase, on the web and video say split ph. in reality, single phase geos to R and T and S have nothing. My 5.5KW draw like 45Amps "Stall" 230VAC and give me a nice 21Amp 3ph. Hey what can I expect for that price... It's working... In my application it's fine but not a 5*. The price make-it better then adding a contactor and over-load and give you allot of controls, power less wiring and more versality. It's a must-have on almost any machines 3 phases. Yes I recommend-it but not for an application that require increase safety or a quoit application …
K**.
Easy choice
Works great, easy setup, I'm using this to run my milling machine.
A**4
Customer support was great they responded right away!
I wanted to give an update on my issue. Huanyang's customer service is top notch. They responded quickly and assured me that they would take care of the issue after Amazon was out of stock on the model that I order and really wanted. Huanyang customer service shipped me a replacement of the model that I originally purchased and wanted. Once I received the replacement VFD and verify it works as expected. I will update this post again. Based on my previous experience with Huanyang VFD I expect it to be excellent quality and performance. That was one of the reasons I was so disappointed when the first one did not power on. I will let everyone know as soon as I get it if it meets my expectations.
H**Y
Easy user interface and easy to program. A lot of third party information about this unit.
Originally ordered a Mollom VFD that was DOA. Instructions were next to none and there was nothing on the internet about them. After an hour of frustration I decided to box the unit up and return it. I ordered this Huanyang and I had it set up in less than 5 minutes. It has an easy user interface and easy to program. The instructions were light years better than the Mollom instruction but, they still has some information missing and or confusing to understand. This unit has a lot of third party videos on how to set it up which ended up answering the questions that were either confusing or missing in the instruction manual. I'm not sure on the longevity but right out of the gate its a winner in my book. I would recommend this to anyone looking for a 3 phase VFD or to convert 1 phase into 3 phase for whatever equipment they are trying to run.
Trustpilot
2 weeks ago
3 days ago